Soft Storey & Stilt Parking: Why Open Ground Floors Fail in Earthquakes

The open stilt-parking floor under many apartment blocks is also their biggest earthquake weakness. Why — and how it's fixed — with SM Structural Consultants, Hyderabad.

Loads & Behaviour8 min readHyderabad

Earthquake Safety

Look at almost any apartment block in an Indian city and you'll see the same thing at street level: an open ground floor on columns, used for parking, with the solid, brick-walled flats stacked above it. It's practical, it's everywhere, and in an earthquake it's the single most dangerous configuration a building can have. Engineers call it a soft storey, and the open stilt-parking floor is its most common form.

At SM Structural Consultants, recognised as one of the top structural consultants in Hyderabad, the soft storey is one of the first things we look for when assessing an existing apartment building — because it turns an otherwise ordinary structure into one where all the earthquake damage concentrates in a single, weak level. This guide explains what a soft storey is, why stilt parking creates one, how it fails, and how it can be designed out or retrofitted.

Upper Floors Move as a Block Stiff, walled storeys sway together, barely bending Brick Infill Walls Stiffen every upper storey — but not the ground Open Ground Floor = Soft Storey No walls, so far more flexible than the floors above Columns Take All the Drift The whole sway is forced into this one storey Plastic Hinges Form Here Column ends yield — and can collapse Ground Shaking The earthquake input at the base
In a soft-storey building the whole earthquake drift concentrates in the open ground floor
Soft (flexible) storey Stiff walled storeys Where it fails

Key Takeaways

  • A soft storey is a level far more flexible (and often weaker) than the storey directly above it.
  • Stilt parking is the classic cause: open columns below, brick-walled flats above.
  • In an earthquake, the sway and damage concentrate almost entirely in that one open storey.
  • The ground columns are forced to absorb the whole building's drift, hinge at their ends, and can collapse.
  • It's extremely common in Indian apartments — and a known cause of collapse in past earthquakes.
  • It can be designed out, or retrofitted, by adding stiffness and strength at the ground floor.
The convenience of an open ground floor is paid for, in an earthquake, by the columns holding it up.
Section 01

What a Soft Storey Really Is

A soft storey is a level in a building that is significantly more flexible than the one above it — in code terms, its lateral stiffness is a fraction of the storey immediately above. In plain terms, it bends sideways far more easily than its neighbours. A closely related idea is the “weak storey”, where the level is not just more flexible but has less strength. In real buildings the two usually come together, and almost always at the same place: the open ground floor.

The reason is that stiffness in a typical building doesn't come only from the columns — it comes just as much from the brick infill walls packed between them. Take those walls away on one level, and you've made that level dramatically more flexible than the rest, whether you meant to or not.

Section 02

Why Stilt Parking Creates One

Stilt parking needs the ground floor kept open — no walls, just columns, so cars can move between them. Every floor above, though, is full of brick partition and external walls that quietly stiffen the frame. The result is a sudden, drastic drop in stiffness at exactly one level: rigid, walled flats sitting on top of a bare, flexible frame. That abrupt change is the soft storey, and it's built in the moment you leave the ground floor open while filling the floors above with walls.

The Setup

Walls Above

Upper floors are stiffened by their brick infill walls, so they hardly deform.

The Setup

Open Below

The ground floor has only columns, so it's far more flexible than every floor above.

The Result

Stiffness Cliff

A sudden jump in flexibility at one level — the definition of a soft storey.

Section 03

How It Fails in an Earthquake

When the ground shakes, a building sways side to side. In a regular building, that sway is shared across every storey, and each one bends a little. In a soft-storey building, the stiff upper floors barely bend — they ride along almost as a single rigid block — so the entire sway is dumped into the one flexible level below. The ground columns are forced to absorb the whole building's movement on their own. They bend into an S-shape, form plastic hinges at their tops and bottoms, and if the drift is large enough those columns fail and the block above drops straight down onto the parking level.

⚠ The Danger Is Invisible Until the Day It Matters

A soft-storey building looks completely normal — and behaves normally — every single day it isn't shaken. There's no crack, no sag, nothing a resident would notice. The weakness only reveals itself in an earthquake, which is exactly why it's so often left unaddressed, and why past earthquakes have seen rows of otherwise sound-looking apartment blocks fail at the stilt floor while neighbouring buildings stood.

Section 04

The Structural Ideas Behind It

A handful of concepts explain why the soft storey behaves the way it does — and why codes single it out.

Stiffness Irregularity

An abrupt change in stiffness up the height concentrates demand at the weak level.

Storey Drift

The sideways movement of one storey relative to the next — huge at a soft storey.

Column Shear & Hinging

Ground columns take intense shear and bending, hinging at their ends.

P-Delta Effect

The weight above, acting through a large sway, worsens the demand on leaning columns.

Code Amplification

IS 1893 requires the soft-storey members to be designed for higher forces.

Redundancy Loss

With no walls to help, the columns alone must resist the earthquake.

Section 05 · A Real Sequence

How It's Prevented or Retrofitted

A soft storey can be designed out in a new building, or strengthened in an existing one. The principle is the same: reduce the stiffness cliff, and make the ground storey strong enough for what the earthquake asks of it.

Identify the Irregularity

Confirm the stiffness and strength drop at the open storey against code criteria.

Design Ground Members for Higher Forces

Apply the code's amplification so the soft-storey columns and beams are sized for the real demand.

Add Stiffness at the Ground Floor

Introduce shear walls or braced bays where they don't block parking, to share the drift.

Strengthen the Columns

Jacket existing ground columns with concrete or steel to add shear and bending capacity.

Check the Foundation

Make sure the new walls and strengthened columns carry their loads safely to the ground.

Review & Code Compliance

Independent review against IS 1893 and IS 13920 before the retrofit is finalised.

Section 06

Myths & Facts

Common BeliefWhat's Actually True
“Stilt parking is banned, so it must be safe.”It's widely allowed — but only when the soft storey is specifically designed for, which is often skipped.
“The building looks fine, so it's fine.”A soft storey shows no everyday symptoms; the weakness only appears in an earthquake.
“More columns at the ground floor fixes it.”Stiffness, not just column count, is the issue — walls or bracing are usually what's needed.
“Nothing can be done to an existing building.”Soft storeys are routinely retrofitted with added walls, bracing, and column jacketing.
Share this article

Related Reading

The soft storey is really a lateral-load problem — these cover the forces, the path, and the fix:

Frequently Asked Questions

A soft storey is a level of a building that is much more flexible — and often weaker — than the storey directly above it. It usually happens where one floor is left open (like a stilt-parking ground floor) while the floors above are stiffened by brick walls. The abrupt drop in stiffness at that level is what makes it dangerous in an earthquake.

Stilt parking can be safe, but only if the soft storey it creates is specifically designed for. Left as an ordinary open frame under walled floors, it becomes the weakest link in an earthquake. When engineers add stiffness and strength at the ground floor — and design its columns for the higher seismic forces — a stilt-parking building can be made to perform well.

Because the stiff upper floors sway almost as a single block, forcing the entire building's sideways movement into the one flexible ground storey. The ground columns must absorb all of that drift alone; they bend, form plastic hinges at their ends, and if the movement is large enough they fail — dropping the block above onto the open level.

The tell-tale sign is an open ground floor — typically stilt parking with only columns — beneath floors that are filled with brick walls. That configuration almost always creates a soft storey. A structural engineer can confirm it by comparing the stiffness of the ground floor with the storeys above, and assess how serious it is.

Yes. Soft storeys are commonly retrofitted by adding stiffness and strength at the ground floor — introducing shear walls or steel bracing where they don't block parking, and jacketing the existing columns with concrete or steel to increase their capacity. The foundation is checked to carry the new loads, and the whole retrofit is designed to code.

Building codes in India generally permit stilt parking, but the seismic code (IS 1893) recognises the soft-storey risk and requires the ground-storey members to be designed for amplified forces. The problem in practice is that this special design is sometimes not carried out, leaving the soft storey unaddressed even where it's technically permitted.

Yes. As one of the top structural consultants in Hyderabad, our team assesses apartment and stilt-parking buildings for soft-storey and other seismic irregularities, and designs retrofits — shear walls, bracing, and column jacketing — to strengthen the ground floor and bring it in line with the seismic code.
Live in or Own a Stilt-Parking Building in Hyderabad?

Find out if your building has a soft storey — before an earthquake does.

Our team assesses apartment blocks for soft-storey and stilt-parking weakness, and designs retrofits — added shear walls, bracing, and column jacketing — to bring the ground floor up to code.

Book a Seismic Assessment
smstructuraldesigns@gmail.com